The Particle Size Analysis of Soil Apparatus determines the distribution of particle sizes within a soil sample. This analysis is crucial for understanding various soil properties such as permeability, compaction, fertility, and stability. It involves preparing a soil suspension by mixing the sample with a dispersing agent and water, then allowing it to settle in a sedimentation cylinder for a specific duration. A sedimentation hydrometer is used to measure the settling rate, providing data for calculating particle size distribution using equations like Stoke’s Law. The results are interpreted to generate a particle size distribution curve, which shows the percentage of particles at different sizes, typically categorized into gravel, sand, silt, and clay fractions. This method offers a quick and cost-effective means of obtaining valuable insights into soil characteristics.
Features of Particle Size Analysis of Soil Apparatus
- Sedimentation Cyclinder designed to hold soil suspension during the settling process.
- Hydrometer measure the settling rate of soil particles in suspension accurately.
- Measurement scale allows for precise reading of the depth to which the hydrometer sinks into the suspension, enabling calculation of settling rates
- Mixing Device used to thoroughly mix the soil sample with water and dispersing agent, ensuring homogeneity and proper suspension of soil particles.
- Calibration Mechanisms help maintain accuracy over time by allowing regular checks and adjustments.
Standard: ASTM D422, AASHTO T88 / UNE 103.102
-
ASTM D422
This standard, titled “Standard Test Method for Particle-Size Analysis of Soils,” provides guidelines for evalauting the particle size distribution of soil samples. It covers methods for both mechanical analysis (sieve analysis) and hydrometer analysis. ASTM D422 outlines procedures for sample preparation, dispersion, analysis, and calculation of particle size distribution. This standard is widely used in various industries, including construction, agriculture, and environmental engineering.
-
AASHTO T88
The standard also known as “Standard Test Method for Particle-Size Analysis of Soils,” offers step-by-step protocols for assessing the distribution of particle sizes within soil samples. It encompasses techniques like mechanical analysis, which employs sieves, and hydrometer analysis. Within this standard, procedures are outlined for preparing samples, dispersing particles, conducting analysis, and calculating particle size distribution. Embraced accross diverse sectors such as construction, agriculture, and environmental engineering, ASTM D422 serves as a cornerstone for reliable soil characterisation methods, facilitating informed decision-making across various industry.
-
UNE 103.102
UNE 103.102 serves as the Spanish standard for analyzing soil particle sizes. While it aligns with the principles of ASTM D422 and AASHTO T88, it caters to Spain’s unique regulations and practices. This standard outlines procedures for both sieve and hydrometer analyses, alongside guidance on sample preparation and result interpretation. Its significance lies in ensuring the accuracy and consistency of soil characterization within Spain and other Spanish-speaking areas.
Testing Procedure of Particle Size Analysis of Soil Apparatus
- Sample Collection: Obtain a representative soil sample from the site of interest. Ensure that the sample is properly labeled and stored to maintain its integrity.
- Pentration of Sample: Clean the sample, break up any clumps and aggregates to ensure a homogenous mixture.
- Method Selection: Decide whether to use mechanical analysis (sieve analysis) or hydrometer analysis, based on the soil type and particle size distribution range.
- Sieve Analysis: To conduct sieve analysis, weigh and sieve soil, record retained soil weights on each sieve, calculate percentages, and plot a particle size distribution curve.
- Hydrometer Analysis: Disperse soil in a dispersing agent solution in a sedimentation cylinder, then allow settling. Measure hydrometer depth and time intervals, then calculate particle size distribution using Stoke’s Law.
- Data Interpretation: Analyse the results obtained from either method to determine the particle size distribution of the soil sample. Compare the distribution curve with standard soil classifications if necessary.
- Quality Control: Ensure that the testing follows relevant standards like ASTM D422, AASHTO T88, UNE 103.102, and confirm proper calibration and functionality of all equipment.
- Reporting: Record the testing process, including sample information, chosen method, results, and any pertinent observations. Ensure that the documentation adheres to applicable regulations and standards.
Technical Specifications of Particle Size Analysis of Soil Apparatus:
| Model Number | 5024 X / 001 | 5024 X / 002 |
| Type | 6 Samples (Standard) | 15 to 20 Samples (Large) |
| Approx. Weight | 19 kg | 26 kg |
| Bath Dimension | 540 x 310 x 410 mm | 830 x 520 x 410 mm |
Set Consists Of:
| STANDARD | ||
| Model Number | Parts Description | Qty |
| 5024 X / 001 – P 001 | Constant Temperature Water Bath c/w Heater & Circulating Pump 240 V, 1 ph, 50 / 60 Hz | 1no. |
| 5024 X / 001 – P 002 | Hydrometer Jar 1000 ml | 6nos. |
| 5024 X / 001 – P 003 | Hydrometer Jar Rubber Bung | 6nos. |
| 7010 G / 002 | Hydrometer Long Stem 0.995 – 1.038 g/ml (ASTM) | 1no. |
| 7034 X / 006 | Glass Thermometer -10°C to 50°C x 0.5°C | 1no. |
| 7002 G / 004 | Glass Beaker with Spout 250 ml | 1no. |
| 7029 CM / 003 | Sodium Hexametaphosphate 1000 g / btl | 1btl. |
| 5024 X / 001 – P 009 | High Speed Stirrer, 10000 RPM c/w cup & Baffle 240 V, 1 ph, 50 / 60 Hz | 1no. |
| LARGE | ||
| Model Number | Parts Description | Qty |
| 5024 X / 002 – P 001 | Constant Temperature Water Bath c/w Heater & Circulating Pump 240 V, 1 ph, 50 / 60 Hz | 2nos |
|
5024 X / 001 – P 002 5024 X / 001 – P 003 7010 G / 002 |
Hydrometer Jar 1000 ml Hydrometer Jar Rubber Bung Hydrometer Long Stem 0.995 – 1.038 g/ml (ASTM) |
15nos. 15nos. 1no. |
| 7034 X / 006 | Glass Thermometer -10°C to 50°C x 0.5°C | 1no. |
| 7002 G / 004 | Glass Beaker with Spout 250 ml | 1no. |
| 7029 CM / 003 | Sodium Hexametaphosphate 1000 g / btl | 1btl. |
| 5024 X / 001 – P 009 | High Speed Stirrer, 10000 RPM c/w cup & Baffle 240 V, 1 ph, 50 / 60 Hz | 1no. |
Optional Accessories:
| Model Number | Accessories Description |
| 7029 CM / 002 | Sodium Carbonate (1000 g) |



Reviews