{"id":20286,"date":"2025-12-09T01:37:09","date_gmt":"2025-12-09T01:37:09","guid":{"rendered":"https:\/\/zainwestern.com\/?post_type=product&#038;p=20286"},"modified":"2025-12-09T01:37:11","modified_gmt":"2025-12-09T01:37:11","slug":"electrical-density-gauge-edg-with-gps-5032-x-002","status":"publish","type":"product","link":"https:\/\/zainwestern.com\/ar\/product\/electrical-density-gauge-edg-with-gps-5032-x-002\/","title":{"rendered":"Electrical Density Gauge (EDG) with GPS\n 5032 X \/ 002"},"content":{"rendered":"<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D7698<\/strong><\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Electrical Density Gauge (EDG)<\/strong><\/span><\/h2>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><span style=\"font-weight: 400;\">The <strong>Electrical Density Gauge (EDG)<\/strong> is a portable and nuclear-free alternative device for determining the moisture and density content of compacted <\/span><span style=\"font-weight: 400;\">soils used in road beds and foundations <\/span><span style=\"font-weight: 400;\">directly in place. The testing involves placing the gauge on the material being tested, and the radioactive source emits gamma radiation which passes through the material and is detected by the sensor on the opposite side. The amount of radiation detected is proportional to the density of the material. By comparing the detected radiation to a calibration curve, the density of the material can be determined including the percentages of compaction, moisture, and wet &amp; dry density.<\/span><\/span><\/p>\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Additionally, the gauge evaluates moisture content by analyzing the attenuation of gamma radiation caused by water presence. This comprehensive analysis ensures the quality and compaction of construction materials, crucial for the durability and performance of infrastructure projects.<\/span><\/p>\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">The EDG is a portable, battery-powered instrument capable of being used anywhere without the concerns and regulations associated with nuclear safety. Its user-friendly, step-by-step menu guides the user through each step of the testing procedure and cautions the user when values do not correspond to established curves for the material being tested.<br \/><\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Features of Electrical Density Gauge (EDG)<\/strong><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Simultaneously measures both density and moisture content of compacted materials, providing comprehensive information in a single test by analyzing the attenuation of gamma radiation caused by water presence.<\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Designed for portability with battery-powered, allowing for its use anywhere without the need for external power sources.<\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Operates on a non-destructive testing principle.<\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Equipped with data logging features for recording and storing measurement data. <\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><span style=\"font-weight: 400;\">Designed for user-friendly interface operation with step-by-step menus that guide users through the testing procedure ensuring that construction teams can easily integrate the EDG into their workflow. <\/span><span style=\"font-weight: 400;\">It also alerts users when values deviate from established curves for the tested material, ensuring accurate results.<\/span><\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Gamma Radiation Detection: Utilizing gamma radiation, the gauge measures the density of the material, providing accurate data for compaction assessment.<\/span><\/p>\n<\/li>\n<li style=\"font-weight: 400;\">\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Comprehensive Analysis: The EDG provides a comprehensive analysis, including percentages of compaction, moisture content, and wet &amp; dry density. This information is crucial for ensuring the quality and durability of construction projects.<\/span><\/p>\n<\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Technical Specifications<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Model<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> <strong>5032 X \/ 002<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Soil Compaction Range<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Standard field compaction range<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Test Range Depth<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 30 cm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Control Device<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Compact steel case with touchscreen <\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Soil Sensor Probe<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Internal Built-In<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Data Transfer<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> USB Port or Bluetooth (Optional)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> GPS Accuracy<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 3 meters<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Wet Density Range<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Typical Compacted Earth Sites Range<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Dry Density Range<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Within 3% of standard tests<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Moisture Content-Range<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Typical Compacted Earth Sites Range<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Moisture Content Accuracy<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Within 2 % of standard tests<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Operating Temperature<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 0 &#8211; 50 \u02daC<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Ambient Operating Humidity<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5 &#8211; 90 %, non-condensing<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Power<\/strong><\/span><\/td>\n<td> <span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Li Ion Battery 12V, 2600mAh; 31 Wh<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Battery Life<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Approx. 20 Hours<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Battery Charger<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 240V 50\/60Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Case Dimensions<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 420(L) x 330(W) x 220(H) mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Weight<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5.5 kg<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Unit Consist Of:<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> <strong>Description<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P001<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Touch Screen Control Device<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P002<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Dart Template<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P003<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 6&#8243; Darts (4 pcs\/set)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P004<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Temperature Probe<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P005<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Hammer<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P006<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Soil Sensor and Cables<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P007<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Solid Waterproof Carry Case<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 5032 X \/ 001 &#8211; P008<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> GPS Device<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">*1 copy of manual instruction<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Standard<\/strong><\/span><\/h2>\n<ol>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D7698<\/strong>: This standard specifies procedures for determining the density and moisture content of compacted asphalt mixtures using a non-nuclear electrical density gauge (EDG).<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D1556<\/strong>: This standard outlines methods for determining the density of soil in place by the sand-cone method or the rubber-balloon method.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D2167<\/strong>: ASTM D2167 provides procedures for laboratory compaction characteristics of soil using standard effort (12,400 ft-lb\/ft\u00b3).<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM 2937<\/strong>: This standard provides methods for the determination of the density of soil in place by the drive-cylinder method.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM 4564<\/strong>: ASTM 4564 specifies procedures for determining the in-place density and moisture content of soil and soil-aggregate using nuclear gauges.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM 6938<\/strong>: This standard details the procedures for field measurement of soil resistivity using the Wenner four-electrode method.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D2216<\/strong>: ASTM D2216 covers the laboratory determination of water content (moisture content) of soil and rock using various methods, such as oven-drying and calcium carbide gas pressure.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D4643<\/strong>: ASTM D4643 describes methods for measuring the moisture content of soil in place using a field moisture probe meter.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D4744<\/strong>: This standard provides guidelines for the field classification of soils and rocks using the Unified Soil Classification System (USCS).<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>ASTM D4959<\/strong>: ASTM D4959 covers the measurement of soil texture by the hydrometer method.<\/span><\/p>\n<\/li>\n<\/ol>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Test Procedure of Electrical Density Gauge (EDG)<\/strong><\/span><\/h2>\n<ul>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Equipment Setup<span style=\"font-weight: 400;\">: Ensure the EDG is in good working condition and calibrated according to the manufacturer&#8217;s instructions. Set up the EDG at the testing site.<\/span><\/b><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Safety Precautions<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Follow all safety protocols, including wearing appropriate personal protective equipment (PPE), especially if working with devices that use nuclear technology.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Calibration Check<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Verify that the EDG is properly calibrated using calibration blocks or procedures specified by the manufacturer. Calibration ensures accurate measurements.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Selection of Testing Locations<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Choose representative locations for testing that accurately reflect the compacted material. Take measurements at various points to assess uniformity.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Preparation of Test Surface<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Ensure the surface of the compacted material is smooth and free from debris. The EDG sensor should make good contact with the material.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Sensor Placement<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Place the EDG sensor on the prepared test surface. Some EDGs may have specific guidelines regarding sensor orientation and positioning.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Data Entry<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Enter any required information into the EDG, such as project details, location identifiers, or test parameters.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Initiate Measurement<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Activate the EDG to initiate the measurement process. Depending on the model, the device may automatically start collecting data.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Data Collection<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Allow the EDG to collect data, including measurements of density and moisture content. The device may use nuclear radiation to measure density and may include additional sensors for moisture content.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Recording Readings<\/strong><span style=\"font-weight: 400;\"><strong>:<\/strong> Record the readings displayed on the EDG. Note both the density and moisture content values.<\/span><\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong><b>Interpretation of Results<\/b><span style=\"font-weight: 400;\">: Interpret the results based on project specifications or applicable standards. Compare the obtained density and moisture content values to project requirements.<\/span><\/strong><\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Product Video<\/strong><\/span><\/h2>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>How to Operate <\/strong><strong>Electrical Density Gauge (EDG)<\/strong><\/span><\/h2>","protected":false},"excerpt":{"rendered":"<p>ASTM D7698 Electrical Density Gauge (EDG) The Electrical Density Gauge (EDG) is a portable and nuclear-free alternative device for determining the moisture and density content of compacted soils used in road beds and foundations directly in place. The testing involves placing the gauge on the material being tested, and the radioactive source emits gamma radiation [&hellip;]<\/p>","protected":false},"featured_media":19201,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[142],"product_tag":[],"class_list":{"0":"post-20286","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-soil-testing-equipments","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product\/20286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/comments?post=20286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media\/19201"}],"wp:attachment":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media?parent=20286"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_brand?post=20286"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_cat?post=20286"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_tag?post=20286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}