{"id":20220,"date":"2025-12-09T01:37:00","date_gmt":"2025-12-09T01:37:00","guid":{"rendered":"https:\/\/zainwestern.com\/?post_type=product&#038;p=20220"},"modified":"2025-12-09T01:37:02","modified_gmt":"2025-12-09T01:37:02","slug":"concrete-impermeabilty-apparatus-digimatic-4022-x-002","status":"publish","type":"product","link":"https:\/\/zainwestern.com\/ar\/product\/concrete-impermeabilty-apparatus-digimatic-4022-x-002\/","title":{"rendered":"Concrete Impermeabilty Apparatus, Digimatic\n 4022 X \/ 002"},"content":{"rendered":"<h2><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Standard: EN 12390-8, DIN 1048<\/strong><\/span><\/h2>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong><span style=\"text-decoration: underline;\">Concrete Impermeability Apparatus<\/span><\/strong><\/span><\/h2>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><b>Concrete Impermeability Apparatus <\/b><span style=\"font-weight: 400;\">is used to determine the permeability of concrete by measuring the depth of water under pressure penetrating concrete specimens and its ability to resist the penetration of water or other fluids. This result provides the durability and lifespan of concrete structures.<\/span><\/span><\/p>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><b>Concrete Impermeability Apparatus<\/b><span style=\"font-weight: 400;\"> consists of a chamber where the concrete sample is placed, and pressure is applied to force water or other fluids through the concrete. The unit accepts concrete cubic, cylindrical, or prismatic specimens having dimensions up to 200 x 200 x 200 mm. The specimen is placed between the quick clamping chamber and the special circular gaskets. The water is under controlled pressure by a fully automatic digital control panel with a high-precision pressure transducer for fined and precision pressure control. The water penetrated is measured by splitting the specimen into half. By measuring the rate or amount of fluid that penetrates the concrete, engineers can assess its impermeability, which is an important factor in determining the durability and lifespan of concrete structures.<\/span><\/span><\/p>\n<p><span style=\"font-weight: 400; font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">The unit comes with standard 6-piece test chambers. Supplied with built air pressure compression and water tank.<\/span><\/p>\n<h2 style=\"text-align: justify;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b><u>Features of Digimatic Concrete Impermeability Apparatus<\/u><\/b><\/span><\/h2>\n<ul>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Versatile Compatibility with various concrete specimen shapes and sizes, up to 200 x 200 x 200 mm.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Quick Clamping System which facilitates easy and secure placement of specimens between chambers with special circular gaskets.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">A fully automatic digital control panel ensures fine and precise pressure control during testing.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">High-precision Pressure Transducer that enables accurate measurement and control of water pressure.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Efficient Water Penetration Measurement by splitting the specimen into halves after testing.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Comes with standard six test chambers for conducting multiple tests simultaneously.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Integrated Air Pressure Compression.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Supplied with Water Tank.<\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Standard: EN 12390-8, DIN 1048<\/strong><\/span><\/h2>\n<ul>\n<li style=\"text-align: justify;\">\n<h3><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">EN 12390-8<\/span><\/h3>\n<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">This standardized method is for evaluating the effectiveness of hardened concrete when it endures water pressure. The test involves subjecting concrete samples to controlled water pressure for a set duration and it evaluates how well they resist penetration. After exposure, the specimens are split open to measure the depth of water penetration. Ultimately. EN 12390-8 safeguards the structural integrity of concrete by providing assurance of its ability to withstand water challenges, thus upholding safety and performance standards in construction projects. <\/span><\/p>\n<ul>\n<li style=\"text-align: justify;\">\n<h3><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>DIN 1048<\/strong><\/span><\/h3>\n<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">This standard is a crucial procedure used to determine the water permeability of hardened concrete. Its primary objective is to assess how effectively concrete resists water penetration, a crucial factor in evaluating its durability for construction applications. The testing procedure achieves its goal by subjecting standardized concrete specimens to controlled water pressure, replicating real-world conditions like heavy rainfall or groundwater pressure. The duration of the test varies based on the concrete type and intended application, ensuring comprehensive evaluation. Following exposure to water pressure, engineers meticulously measure the rate of water permeability through the specimens. Lower permeability rates indicate better resistance, signifying higher durability and suitability for construction.  Ultimately, DIN 1048 ensures standardized testing methods to uphold quality and durability standards in concrete structures across construction projects.<\/span><\/p>\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong><span style=\"text-decoration: underline;\">Test Procedure of Concrete Impermeability Apparatus<\/span><\/strong><\/span><\/h2>\n<ol>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Sample Preparation:<\/strong> Prepare the concrete specimens according to the standard procedures, ensuring they represent the material used in the structure. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Conditioning: <\/strong>The samples are subjected to specific temperature and humidity conditions for a set period to ensure they reflect real-world scenarios.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Testing Setup:<\/strong> Set up the Concrete Impermeability Apparatus according to the manufacturer&#8217;s instructions. Ensure that all connections are secure and that the apparatus is calibrated correctly. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Sample Placement:<\/strong> Concrete samples are securely positioned within the apparatus, ensuring no leakage occurs during testing. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Pressure Application:<\/strong> Pressure is applied to the samples using the apparatus. The pressure simulates the conditions the concrete would face in real-world applications, such as water pressure in a water-retaining structure. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Digital Monitoring: <\/strong>Using advanced Digimatic technology, the apparatus digitally monitors and records permeability measurements, including pressure levels and flow rates.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Data Analysis:<\/strong> Analyse the data collected from the test to determine the permeability characteristics of the concrete. This analysis may involve comparing the results to established standards or specifications to assess the concrete&#8217;s suitability for its intended application. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Reporting:<\/strong> Test results, including equipment used and testing conditions, are documented for future reference and comparison. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Quality Assurance:<\/strong> Perform any necessary quality control checks on the test to ensure test accuracy and reliability, which may involve repeating tests or conducting additional analyses as needed. <\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Interpretation: <\/strong>Results are interpreted within the context of project requirements, guiding decisions on concrete suitability and potential areas for improvement in construction practices or concrete mixes.<\/span><\/li>\n<\/ol>\n<h2 style=\"text-align: justify;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong><span style=\"text-decoration: underline;\">Technical Specifications:<\/span><\/strong><\/span><\/h2>\n<table border=\"1\" style=\"border-color: #000000;\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> 4022 X \/ 002<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Standard of Test Chamber<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 6 Chamber<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Maximum Size of Specimen<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">  Cubic \/ Cylindrical \/ Prismatic specimens diameter \/ height not more than 200 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Pump Maximum Pressure<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 1 Mpa (10 bar)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Dimension (LxWxH)<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 770 x 1050 x 1450 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Weight<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 150 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Power<\/strong><\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 220~240 V, 1 Ph, 50\/60 Hz, 500 W<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong><span style=\"text-decoration: underline;\">Unit Consists Of:<\/span><\/strong> <\/span><\/h2>\n<table border=\"1\" style=\"border-color: #000000;\">\n<tbody>\n<tr>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Model Number<\/strong><\/span><\/td>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Parts Description<\/strong><\/span><\/td>\n<td style=\"width: 223.264px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Qty<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 4022 X \/ 002 \u2013 P001<\/span><\/td>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Test Chamber c\/w Gasket Seal<\/span><\/td>\n<td style=\"width: 223.264px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 6 Units<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 4022 X \/ 002 \u2013 P002<\/span><\/td>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Stainless Steel Chamber Guide Tray<\/span><\/td>\n<td style=\"width: 223.264px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 1no.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 4022 X \/ 002 \u2013 P003<\/span><\/td>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Tubing Roll (pre-installed)<\/span><\/td>\n<td style=\"width: 223.264px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 1set<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 223.229px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 4022 X \/ 002 \u2013 P004<\/span><\/td>\n<td style=\"width: 223.229px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Plastic Aspirator Bottle 5L<\/span><\/td>\n<td style=\"width: 223.264px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 1no<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong><span style=\"text-decoration: underline;\">Optional Accessories: <\/span><\/strong><\/span><\/h2>\n<table border=\"1\" style=\"border-color: #000000;\">\n<tbody>\n<tr>\n<td style=\"width: 339.514px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Model Number<\/strong><\/span><\/td>\n<td style=\"width: 339.514px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong> Parts Description<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 339.514px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> 4022 X \/ 002 \u2013 A003<\/span><\/td>\n<td style=\"width: 339.514px;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"> Gasket Seal (O Ring \u00d87 x ID74 mm)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Standard: EN 12390-8, DIN 1048 Concrete Impermeability Apparatus Concrete Impermeability Apparatus is used to determine the permeability of concrete by measuring the depth of water under pressure penetrating concrete specimens and its ability to resist the penetration of water or other fluids. This result provides the durability and lifespan of concrete structures. Concrete Impermeability Apparatus [&hellip;]<\/p>","protected":false},"featured_media":19128,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[141],"product_tag":[],"class_list":{"0":"post-20220","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-concrete-testing-equipments","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product\/20220","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/comments?post=20220"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media\/19128"}],"wp:attachment":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media?parent=20220"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_brand?post=20220"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_cat?post=20220"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_tag?post=20220"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}