{"id":20179,"date":"2025-12-09T01:36:54","date_gmt":"2025-12-09T01:36:54","guid":{"rendered":"https:\/\/zainwestern.com\/?post_type=product&#038;p=20179"},"modified":"2025-12-09T01:36:55","modified_gmt":"2025-12-09T01:36:55","slug":"accelerated-concrete-curing-tank-4007-x-011","status":"publish","type":"product","link":"https:\/\/zainwestern.com\/ar\/product\/accelerated-concrete-curing-tank-4007-x-011\/","title":{"rendered":"Accelerated Concrete Curing Tank\n 4007 X \/ 011"},"content":{"rendered":"<h2><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Standard: ASTM C684 (Method A &amp; Method B), BS1881:112<\/strong><\/span><\/h2>\n<h2><span style=\"text-decoration: underline; font-size: 10pt;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\"><b>Accelerated Concrete Curing Tank<\/b><\/span><\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-size: 10pt;\"><b>Accelerated Concrete Curing Tank<\/b><span style=\"font-weight: 400;\"> is used to accelerate the curing process of concrete specimens. Curing is the process of maintaining adequate moisture and temperature conditions to allow concrete to achieve its desired strength and durability. <\/span>Accelerated curing tanks create an environment that promotes faster curing by controlling factors like temperature and humidity. This helps in reducing the time required for concrete specimens to achieve sufficient strength for testing or use in construction projects. These tanks are particularly useful in situations where there is a need to speed up the construction process or when testing schedules demand quick results. Applicable for accelerating curing for concrete at construction sites and scientific research institutes for prefabricating. It predicts the strengths of rupture and resistance to compression of concrete for 7 days and 28 days for concrete molding using accelerating curing. It is a kind of special device for the quality control of concrete.<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><b>Features of Accelerated Concrete Curing Tank<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400; text-align: justify;\"><span style=\"font-size: 10pt;\"><b>Temperature Control: <\/b><span style=\"font-weight: 400;\">Feature precise temperature control mechanisms with a Range of Temperature up to Ambient ~ 90\u00b0C to maintain the desired curing temperature for the concrete specimens. This control ensures that the curing process occurs at the optimal temperature for accelerated strength development.<\/span><\/span><\/li>\n<li style=\"font-weight: 400; text-align: justify;\"><span style=\"font-size: 10pt;\"><b>Humidity Control:<\/b><span style=\"font-weight: 400;\"> Control over humidity levels is crucial for effective curing. Accelerated curing tanks may include humidity control systems to create and maintain the required moisture conditions for proper concrete hydration.<\/span><\/span><\/li>\n<li style=\"font-weight: 400; text-align: justify;\"><span style=\"font-size: 10pt;\"><b>Programmable Settings: <\/b><span style=\"font-weight: 400;\">Offer programmable settings for temperature and humidity, allowing users to customize curing conditions based on specific project requirements or testing standards.<\/span><\/span><\/li>\n<li style=\"font-weight: 400; text-align: justify;\"><span style=\"font-size: 10pt;\"><b>Stainless Steel Shelves: <\/b><span style=\"font-weight: 400;\">Corrosion-resistant, easy to clean for supporting concrete specimens during the curing process. These shelves provide a stable and hygienic surface for placing the specimens, ensuring they remain securely positioned throughout the curing period. <\/span><\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-size: 10pt;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\"><strong>Standard: ASTM C684, BS1881:112<\/strong><\/span><\/span><\/h2>\n<ul>\n<li>\n<h3><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>ASTM C684<\/b><\/span><\/h3>\n<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Outlines procedures for making and testing cylindrical concrete specimens under controlled conditions, including accelerated curing methods. The standard provides guidelines for preparing and curing concrete specimens for compression testing, with specific requirements for curing temperatures and durations to accelerate the curing process.<\/span><\/p>\n<ul>\n<li>\n<h3><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>BS 1881:112<\/b><\/span><\/h3>\n<\/li>\n<\/ul>\n<p><span style=\"font-size: 10pt;\">Specifies procedures for determining the compressive strength of concrete specimens, particularly cylindrical specimens, using compression testing methods. BS 1881:112 details the preparation, curing, and testing procedures for concrete specimens to assess their compressive strength, which is a crucial parameter for evaluating the quality and performance of concrete in construction projects.<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><b>Test Procedure of Accelerated Concrete Curing Tank<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Preparation of Concrete Specimens: <\/b><span style=\"font-weight: 400;\">Prepare cylindrical concrete specimens according to the required dimensions and mix design specifications. Ensure that the specimens are properly compacted and free from any defects or air voids.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Setting Up the Accelerated Curing Tank:<\/b><span style=\"font-weight: 400;\"> Place the accelerated concrete curing tank in a suitable location with access to power and water sources. Ensure that the tank is level and stable.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Temperature and Humidity Calibration: <\/b><span style=\"font-weight: 400;\">Calibrate the temperature and humidity control systems of the tank to the desired curing conditions specified in the testing standard or project requirements. This may involve setting the temperature and humidity levels according to the accelerated curing schedule.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Placement of Concrete Specimens: <\/b><span style=\"font-weight: 400;\">Carefully place the prepared concrete specimens on the shelves or racks inside the curing tank, ensuring that they are properly spaced and supported to prevent any movement during curing.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Initiating Accelerated Curing: <\/b><span style=\"font-weight: 400;\">Activate the curing cycle of the tank to begin the accelerated curing process. Monitor the temperature and humidity levels continuously throughout the curing period to ensure they remain within the specified range.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Curing Duration: <\/b><span style=\"font-weight: 400;\">Allow the concrete specimens to cure inside the tank for the designated period, as per the testing standard or project requirements. This duration may vary depending on the accelerated curing method used and the desired strength development of the concrete.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Quality Control and Monitoring:<\/b><span style=\"font-weight: 400;\"> Regularly inspect the concrete specimens during the curing process for any signs of cracking, deformation, or other defects. Adjust the curing conditions if necessary to maintain optimal curing parameters.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>End of Curing Cycle: <\/b><span style=\"font-weight: 400;\">Once the curing period is complete, deactivate the curing cycle of the tank and allow the specimens to reach ambient temperature gradually.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Removal of Concrete Specimens:<\/b><span style=\"font-weight: 400;\"> Carefully remove the cured concrete specimens from the tank, taking precautions to prevent any damage or disturbance to the specimens.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt;\"><b>Testing of Concrete Specimens: <\/b><span style=\"font-weight: 400;\">Conduct compression tests on the cured concrete specimens according to the applicable testing standard (e.g., ASTM C684 or BS 1881:112) to determine their compressive strength and other mechanical properties.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-size: 10pt;\">Recording and Reporting: Record all relevant data and observations obtained during the curing and testing process. Prepare a detailed report documenting the test results, including the compressive strength values of the concrete specimens.<\/span><\/li>\n<\/ul>\n<h2> <\/h2>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong><span style=\"text-decoration: underline;\">Technical Specifications of Accelerated Concrete Curing Tank:<\/span><\/strong><\/span><\/h2>\n<table border=\"1\" style=\"border-color: #000000;\">\n<tbody>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> 4007 X \/ 011<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Range of Temperature<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Ambient ~ 100\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Material<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Fully Stainless Steel (G304)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Capacity<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Cylinders:<br \/> \u00d8100 x 200, up to 30 nos (2 layers)<br \/> \u00d8150 x 300, up to 12 nos (1 layers)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Working Space (mm)<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 945 (L) x 720 (W) x 620 (H)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Overall Dimension (mm) <\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 1480 (L) x 850 (W) x 870 (H)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Approx. Weight<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 120 kg <\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Power<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 415 V, 50 \/ 60 Hz, 3 ph, 6.6 KW <\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong><span style=\"text-decoration: underline;\">Unit Consists Of:<\/span><\/strong><\/span><\/h2>\n<table border=\"1\" style=\"border-color: #000000;\">\n<tbody>\n<tr>\n<td style=\"width: 113.328px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Model Number<\/strong><\/span><\/td>\n<td style=\"width: 113.328px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Descriptions<\/strong><\/span><\/td>\n<td style=\"width: 113.344px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong> Qty<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 113.328px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 4007 X \/ 001 &#8211;   P001<\/span><\/td>\n<td style=\"width: 113.328px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> Stainless Steel   Shelves<\/span><\/td>\n<td style=\"width: 113.344px;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"> 2nos.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Standard: ASTM C684 (Method A &amp; Method B), BS1881:112 Accelerated Concrete Curing Tank Accelerated Concrete Curing Tank is used to accelerate the curing process of concrete specimens. Curing is the process of maintaining adequate moisture and temperature conditions to allow concrete to achieve its desired strength and durability. Accelerated curing tanks create an environment that [&hellip;]<\/p>","protected":false},"featured_media":19042,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[141],"product_tag":[],"class_list":{"0":"post-20179","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-concrete-testing-equipments","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product\/20179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/comments?post=20179"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media\/19042"}],"wp:attachment":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media?parent=20179"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_brand?post=20179"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_cat?post=20179"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_tag?post=20179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}