{"id":20053,"date":"2025-12-09T01:36:32","date_gmt":"2025-12-09T01:36:32","guid":{"rendered":"https:\/\/zainwestern.com\/?post_type=product&#038;p=20053"},"modified":"2025-12-09T01:36:35","modified_gmt":"2025-12-09T01:36:35","slug":"sieve-shaker-magnetic-triple-motion-1015-x-010n","status":"publish","type":"product","link":"https:\/\/zainwestern.com\/ar\/product\/sieve-shaker-magnetic-triple-motion-1015-x-010n\/","title":{"rendered":"Sieve Shaker, Magnetic, Triple Motion\n 1015 X \/ 010N"},"content":{"rendered":"<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Standard: EN 932-5, ISO 3310-1<\/strong><\/span><\/p>\n<p><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Sieve Shaker, Magnetic, Triple Motion<\/b><\/span><\/p>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><span style=\"font-weight: 400;\">A<strong>?Sieve Shaker<\/strong>?with magnetic features for better sieve attachment is used to shake or agitate a stack of sieves to separate particles based on their size. Sieves are mesh-like devices with uniform holes of different sizes. When a sample is placed on the top sieve and the stack is shaken, particles smaller than the openings in the sieve fall through, while larger particles remain on top. This process is commonly used in various industries and research fields to analyze particle size distribution in materials such as soil, aggregates, pharmaceuticals, and food products. Unlike traditional sieve shakers that typically employ only vertical or horizontal motion,Scientific provides the triple motion sieve shaker that combines three types of motions:?<\/span><b>Vertical Motion, Horizontal Motion, and Rotational Motion.<\/b><\/span><\/p>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">This magnetic technology allows for quick and effortless attachment and ensures a secure fixation of the sieves during the sieving process. By securely holding the sieves in place, the magnetic attachment promotes uniform distribution of motion, enhancing the efficiency and accuracy of particle size analysis.<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Type of Sieve Shaker Motion Settings<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Vertical Motion:?<\/b><span style=\"font-weight: 400;\">This motion helps to move the particles through the sieve openings, ensuring proper separation.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Horizontal Motion:?<\/b><span style=\"font-weight: 400;\">It ensures that the particles are evenly distributed across the sieve surface, preventing clogging and ensuring accurate results.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Rotational Motion:?<\/b>This motion mimics the rotational motion of the sieve, aiding in the passage of particles through the sieve mesh.<\/span><\/li>\n<\/ul>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><span style=\"text-decoration: underline;\"><b>Features of?<\/b><\/span><span style=\"text-decoration: underline;\"><b>Sieve Shaker, Magnetic Triple Motion<\/b><\/span><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Triple Motion Functionality:?<\/b><span style=\"font-weight: 400;\">Incorporates vertical, horizontal, and rotational motions to ensure thorough and efficient sieving.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Low noise pollution<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">Comes with a vibration control potentiometer. The user can effortlessly adjust and customize the vibration speed to their preferences.<\/span><\/li>\n<\/ul>\n<p><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Technical Specifications of?Sieve Shaker, Magnetic Triple Motion<\/strong><\/span><\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>?NL 1015 X \/ 010N<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>?Sieves Diameter<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?200 &amp; 300 mm, 8? &amp; 12? Diameter<br \/><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>?Timer<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?1 &#8211; 60 min<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\"><strong><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\">?Sieve Max Capacity?<\/span><\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?up to 10 nos.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\"><strong><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\">?Product Dimension<\/span><\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?540 (L) x 460 (W) x 1230 (H) mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\"><strong><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\">?Packing Dimension<\/span><\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?640 (L) x 560 (W) x 1330 (H) mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\"><strong><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\">?Approx. Weight<\/span><\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?62 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt;\"><strong><span style=\"font-family: tahoma, arial, helvetica, sans-serif;\">?Power<\/span><\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?220~240 V, 400 W, 1 Ph, 50 \/ 60 Hz<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Unit Consists Of:<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Parts Description<br \/><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?NL 1015 X \/ 006 ? P 001<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Clamping Knobs (Pair of 2)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?NL 1015 X \/ 006 ? P 002<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Clamping Beam<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?NL 1015 X \/ 006 ? P 003<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">?Threaded Rod c\/w Extended Rod<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?NL 1015 X \/ SC1<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Shaker Smartz Controller <\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">*1 Copy of Manual Instruction<\/span><\/p>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><span style=\"text-decoration: underline;\"><strong>Optional Accessories of?<\/strong><\/span><span style=\"text-decoration: underline;\"><b>Sieve Shaker, Magnetic, Triple Motion<\/b><\/span><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Parts Description<br \/><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">?NL 1015 X \/ SPC<\/span><\/td>\n<td><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\">?Noise Reduction Cabinet<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Standards<\/b><\/span><\/h2>\n<ul>\n<li>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>EN 932-5<\/strong>: This standard is part of the European Norm (EN) series and specifies the method for the determination of the percentage of particles retained on sieves after sieving aggregates for concrete. It outlines procedures for preparing the test sample, selecting appropriate sieves, conducting the sieving process, and calculating the particle size distribution based on the results obtained.<\/span><\/p>\n<\/li>\n<li>\n<p><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><strong>ISO 3310-1<\/strong>: This standard is issued by the International Organization for Standardization (ISO) and provides specifications for test sieves used in particle size analysis of materials such as aggregates, ores, and powders. ISO 3310-1 defines the requirements for the construction, dimensions, and tolerances of test sieves, ensuring consistency and accuracy in particle size analysis across different laboratories and testing procedures.<\/span><\/p>\n<\/li>\n<\/ul>\n<h2><span style=\"font-size: 10pt; font-family: tahoma, arial, helvetica, sans-serif;\"><span style=\"text-decoration: underline;\"><b>Test Procedure of?<\/b><\/span><span style=\"text-decoration: underline;\"><b>Sieve Shaker, Magnetic, Triple Motion<\/b><\/span><\/span><\/h2>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Preparation of Sample:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Ensure that the sample to be sieved is representative and properly prepared according to the specific testing requirements.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">If necessary, reduce the sample size to an appropriate amount that can be accommodated by the sieves without overloading.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Selection of Sieves:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Choose the appropriate set of sieves with mesh sizes suitable for the desired particle size distribution analysis.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Stack the sieves in ascending order of mesh size, with the finest sieve at the bottom and the coarsest sieve at the top.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Assembling the Sieve Stack:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Place the stack of sieves securely onto the sieve shaker platform, ensuring that each sieve is properly nested within the next one and that the stack is stable.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Setting Parameters:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Adjust the settings on the Triple Motion Sieve Shaker according to the specifications of the test method and the characteristics of the sample.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Set the desired shaking speed, duration, and type of motion (vertical, horizontal, tapping) based on the requirements of the analysis.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Starting the Shaker:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Start the Triple Motion Sieve Shaker to initiate the sieving process.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Monitor the shaking action to ensure that the sample is being properly agitated and sieved.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Observation and Inspection:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Periodically inspect the sieves during the sieving process to check for any signs of clogging or irregularities.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">If necessary, adjust the shaking parameters or stop the shaker to address any issues that may arise.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Completion of Sieving:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Once the sieving process is complete, stop the Triple Motion Sieve Shaker and remove the stack of sieves from the platform.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Carefully disassemble the sieves and inspect the retained material on each sieve for further analysis.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Analysis of Results:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Weigh the retained material on each sieve to determine the mass fraction of particles retained at each size fraction.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Calculate the particle size distribution based on the mass fractions and the mesh sizes of the sieves used.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Cleaning and Maintenance:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Clean the sieves and the sieve shaker platform thoroughly after use to remove any residual material and prevent contamination.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Perform routine maintenance on the Triple Motion Sieve Shaker as recommended by the manufacturer to ensure its proper functioning and longevity.<\/span><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Standard: EN 932-5, ISO 3310-1 Sieve Shaker, Magnetic, Triple Motion A?Sieve Shaker?with magnetic features for better sieve attachment is used to shake or agitate a stack of sieves to separate particles based on their size. Sieves are mesh-like devices with uniform holes of different sizes. When a sample is placed on the top sieve and [&hellip;]<\/p>","protected":false},"featured_media":17825,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[82],"product_tag":[],"class_list":{"0":"post-20053","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-aggregate-rock-testing-equipments","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product\/20053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/comments?post=20053"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media\/17825"}],"wp:attachment":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media?parent=20053"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_brand?post=20053"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_cat?post=20053"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_tag?post=20053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}