{"id":20052,"date":"2025-12-09T01:36:32","date_gmt":"2025-12-09T01:36:32","guid":{"rendered":"https:\/\/zainwestern.com\/?post_type=product&#038;p=20052"},"modified":"2025-12-09T01:36:34","modified_gmt":"2025-12-09T01:36:34","slug":"sieve-shaker-triple-motion-from-200-up-to-450-mm-dia-1015-x-009a","status":"publish","type":"product","link":"https:\/\/zainwestern.com\/ar\/product\/sieve-shaker-triple-motion-from-200-up-to-450-mm-dia-1015-x-009a\/","title":{"rendered":"Sieve Shaker, Triple Motion (From 200 Up To 450 Mm Dia.)\n 1015 X \/ 009A"},"content":{"rendered":"<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Standard: EN 932-5, ISO 3310-1<\/strong><\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Sieve Shaker, Triple Motion from 200 up to 450 mm Dia.<\/b><\/span><\/h2>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><span style=\"font-weight: 400;\">A<strong>?Sieve Shaker<\/strong>?is used to shake or agitate a stack of sieves to separate particles based on their size. Sieves are mesh-like devices with uniform holes of different sizes. When a sample is placed on the top sieve and the stack is shaken, particles smaller than the openings in the sieve fall through, while larger particles remain on top. This process is commonly used in various industries and research fields to analyze particle size distribution in materials such as soil, aggregates, pharmaceuticals, and food products. Unlike traditional sieve shakers that typically employ only vertical or horizontal motion,Scientific provides the triple motion sieve shaker that combines three types of motions:?<\/span><b>Vertical Motion, Horizontal Motion, and Rotational Motion.<\/b><\/span><\/p>\n<p><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">This Diameter Triple Motion Sieve Shaker Series designed byScientific is our largest sieve shaker with a sieving area of up to 450 mm Dia. This allows researchers to test the samples with larger sieving surface diameters.??<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Type of Sieve Shaker Motion Settings<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Vertical Motion:?<\/b><span style=\"font-weight: 400;\">This motion helps to move the particles through the sieve openings, ensuring proper separation.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Horizontal Motion:?<\/b><span style=\"font-weight: 400;\">It ensures that the particles are evenly distributed across the sieve surface, preventing clogging and ensuring accurate results.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Rotational Motion:?<\/b>This motion mimics the rotational motion of the sieve, aiding in the passage of particles through the sieve mesh.<\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Features of Sieve Shaker, Triple Motion<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Triple Motion Functionality:?<\/b><span style=\"font-weight: 400;\">Incorporates vertical, horizontal, and rotational motions to ensure thorough and efficient sieving.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Variable Speed Control:?<\/b><span style=\"font-weight: 400;\">Allows users to adjust the shaking intensity according to the specific requirements of their sample.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Digital Timer:<\/b><span style=\"font-weight: 400;\">?Enables precise control throughout the sieving process, ensuring consistency and repeatability.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Low Noise Pollution<\/strong><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Quick clamping &amp; release mechanism hand knob<\/strong><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Durable Construction:?<\/b><span style=\"font-weight: 400;\">Built with robust materials to withstand continuous use in laboratory environments.<\/span><\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Technical Specifications?of Sieve Shaker, Triple Motion<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?NL 1015 X \/ 009A<br \/><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Accommodates<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?*11 nos 200 mm \/ 8? Dia. Full Height Sieves plus lid and receiver<br \/>?*9 nos 300 mm \/ 12? Dia. Full Height Sieves plus lid and receiver<br \/>?*7 nos. 450 mm Dia. Full Height Sieves plus lid and pan.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Timer<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?1 &#8211; 60 min<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Approx. Dimension<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?585 (L) x 460 (W) x 1250 (H) mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Approx. Weight<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?105 kg<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Power<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?220 V, 1 ph, 1\/2 Hp, 50 \/ 60 Hz, 375W<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Unit Consists Of:<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Parts Description<br \/><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?NL 1015 X \/ 006 ? P 001<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Clamping Knobs (Pair of 2)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?NL 1015 X \/ 009 ? P 004<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Clamping Beam<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?NL 1015 X \/ 006 ? P 003<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Threaded Column Set (pair of 2 included nut &amp; spring washer)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 10pt;\">*1 Copy of Manual Instruction<\/span><\/p>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>Optional Accessories of Sieve Shaker, Triple Motion<\/strong><\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Model Number<\/strong><\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><strong>?Parts Description<br \/><\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?NL 1015 X \/ SPC<\/span><\/td>\n<td><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">?Noise Reduction Cabinet<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Standards<\/b><\/span><\/h2>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>EN 932-5:?<\/b><span style=\"font-weight: 400;\">This standard is part of the European Norm (EN) series and specifically pertains to &#8220;Tests for general properties of aggregates.&#8221; EN 932-5 outlines the methods for the determination of the particle size distribution of aggregates by sieving. It provides guidelines and procedures for conducting sieve analysis to determine the size distribution of aggregates used in construction materials.<\/span><\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>ISO 3310-1:?<\/b><span style=\"font-weight: 400;\">This standard is issued by the International Organization for Standardization (ISO) and is titled &#8220;Test sieves &#8212; Technical requirements and testing &#8212; Part 1: Test sieves of metal wire cloth.&#8221; ISO 3310-1 specifies the technical requirements and testing procedures for test sieves made of metal wire cloth used in particle size analysis. It covers aspects such as sieve construction, dimensions, tolerances, and testing methods to ensure the quality and accuracy of test sieves.<\/span><\/span><\/li>\n<\/ul>\n<h2><span style=\"text-decoration: underline; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Test Procedure of Sieve Shaker, Triple Motion<\/b><\/span><\/h2>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Preparation of Sample:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Ensure that the sample to be sieved is representative and properly prepared according to the specific testing requirements.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">If necessary, reduce the sample size to an appropriate amount that can be accommodated by the sieves without overloading.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Selection of Sieves:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Choose the appropriate set of sieves with mesh sizes suitable for the desired particle size distribution analysis.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Stack the sieves in ascending order of mesh size, with the finest sieve at the bottom and the coarsest sieve at the top.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Assembling the Sieve Stack:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Place the stack of sieves securely onto the sieve shaker platform, ensuring that each sieve is properly nested within the next one and that the stack is stable.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Setting Parameters:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Adjust the settings on the Triple Motion Sieve Shaker according to the specifications of the test method and the characteristics of the sample.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Set the desired shaking speed, duration, and type of motion (vertical, horizontal, tapping) based on the requirements of the analysis.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Starting the Shaker:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Start the Triple Motion Sieve Shaker to initiate the sieving process.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Monitor the shaking action to ensure that the sample is being properly agitated and sieved.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Observation and Inspection:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Periodically inspect the sieves during the sieving process to check for any signs of clogging or irregularities.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">If necessary, adjust the shaking parameters or stop the shaker to address any issues that may arise.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Completion of Sieving:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Once the sieving process is complete, stop the Triple Motion Sieve Shaker and remove the stack of sieves from the platform.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Carefully disassemble the sieves and inspect the retained material on each sieve for further analysis.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Analysis of Results:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Weigh the retained material on each sieve to determine the mass fraction of particles retained at each size fraction.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Calculate the particle size distribution based on the mass fractions and the mesh sizes of the sieves used.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\"><b>Cleaning and Maintenance:<\/b><\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Clean the sieves and the sieve shaker platform thoroughly after use to remove any residual material and prevent contamination.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400; font-family: tahoma, arial, helvetica, sans-serif; font-size: 10pt;\">Perform routine maintenance on the Triple Motion Sieve Shaker as recommended by the manufacturer to ensure its proper functioning and longevity.<\/span><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Standard: EN 932-5, ISO 3310-1 Sieve Shaker, Triple Motion from 200 up to 450 mm Dia. A?Sieve Shaker?is used to shake or agitate a stack of sieves to separate particles based on their size. Sieves are mesh-like devices with uniform holes of different sizes. When a sample is placed on the top sieve and the [&hellip;]<\/p>","protected":false},"featured_media":17822,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[82],"product_tag":[],"class_list":{"0":"post-20052","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-aggregate-rock-testing-equipments","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product\/20052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/comments?post=20052"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media\/17822"}],"wp:attachment":[{"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/media?parent=20052"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_brand?post=20052"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_cat?post=20052"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zainwestern.com\/ar\/wp-json\/wp\/v2\/product_tag?post=20052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}